Restoring NBIS Compliance Through Large-Scale Foundation Evaluation

BDI partnered with the Louisiana Department of Transportation and Development (LADOTD) to evaluate the foundation configuration of nearly 350 bridges across Districts 02 and 62 as part of the agency’s ongoing bridge inspection and asset management program. Because each bridge carried an Unknown Foundation rating from previous inspections, the LADOTD needed to determine foundation data…

Read More

Evaluating Unknown Bridge Foundations Across Texas with Ultraseismic Testing

The Texas Department of Transportation (TxDOT) contracted BDI to evaluate unknown bridge foundations at 48 bridges across Texas. As part of TxDOT’s bridge inspection program, the project focused on assessing foundation condition and scour vulnerability to support National Bridge Inspection Standards (NBIS) reporting requirements. To gather critical foundation data, BDI performed detailed field inspections and…

Read More

Telecom Tower Foundation Evaluation

Telecom tower owners rely on accurate foundation information to support asset management decisions, structural analyses, and antenna upgrades. When design drawings are unavailable or unreliable, BDI helps owners determine foundation dimensions without costly excavation. For more than a decade, BDI has performed unknown foundation investigations for telecommunications infrastructure using advanced nondestructive testing technologies. Engineers first…

Read More

Ultrasonic Testing of Spillway Gate Anchor Bars

BDI was contracted by the Grant County Public Utility District to evaluate the condition of spillway gate anchor bars at Priest Rapids Dam in Washington State. As a key component of the Columbia River hydroelectric system, the dam relies on these concrete embedded anchor bars to safely support and operate its spillway gates. Because the…

Read More

UHPC Overlay Bond Strength Evaluation

The Delaware Memorial Bridge, which carries I-295 across the Delaware River between Delaware and New Jersey, is a critical transportation link for the region. As part of preservation efforts the Delaware River Bridge Authority had an ultra-high performance concrete (UHPC) deck installed on the bridge deck. To evaluate the effectiveness of the repair, BDI was…

Read More

Drone-Assisted Bridge Inspection of I-380 Over the Delaware and Lackawanna Railroad

BDI partnered with engineers to support a routine National Highway Institute (NHI) bridge inspection of the I-380 Bridge over the Delaware and Lackawanna Railroad near Scranton, Pennsylvania. The bridge’s complex geometry and challenging access conditions made traditional bridge inspection methods less efficient, creating an ideal application for drone-based bridge inspection technology. To improve inspection coverage…

Read More

Marshall Space Flight Center NDT-E

BDI was contracted to provide the inspection, evaluation, and testing of the Marshall Space Flight Center Test Stand 4670 in Huntsville, Alabama, specifically levels 12-15. The Test Stand consists of four post-tensioned concrete legs that are 30 square ft along the top and 48 square feet along the bottom. These four legs support a platform…

Read More

Mid-Centre County Wastewater Treatment Plant – Structural Monitoring and Nondestructive Evaluation

Project Description As part of Herbert, Rowland & Grubic, Inc.’s evaluation of cracking observed at the Mid-Centre County Wastewater Treatment Plant (WWTP), BDI was requested to help the evaluation process by monitoring key areas of the facility during operational and seasonal periods to aid in identifying the root cause of the deterioration found on site.…

Read More

BDI’s Charles Young Featured in Hydro Leader Feb Issue

Check out BDI’s own Charlie Young in this month’s issue of the Hydro Leader magazine. Charlie discusses his own professional journey as well as BDI’s history in providing technical expertise and field services for the hydropower sector.

Read More

Diagnostic Load Testing for Bridge Load Rating

Introduction Ask any bridge engineer and they will tell you that a load rating is only as good as the assumptions that it’s based upon. When evaluating bridges, load ratings performed using traditional analysis methods can sometimes be overly conservative and result in unnecessary load restrictions. Section 8 of the AASHTO Manual for Bridge Evaluation…